![]() ![]() If inflow is small, a two to three inch rise is all that is needed to calculate inflow. If inflow occurred during the drawdown test, an inflow test can be performed immediately following drawdown. The spreadsheet will calculate the wet volume per foot, the drawdown volume and the flow rate based upon that information. If this cannot be done, choose a time during the day when inflow is minimal.Īs seen in Figure 1, entering the wet well diameter, drawdown distance and drawdown time is the only data needed if there is no inflow. It is always best to shut off the invert once the pump start level is reached in order to obtain the greatest accuracy. The distance can be measured with a laser device, a plumb bob or a rod with starting and ending markings. The reason one foot is a preferred distance is that it provides for an ample time measurement and flow changes very little over a single foot. Usually a drawdown test measures the time required to remove one foot of water starting at the pump on level. The equations used for the calculations are shown to the right of the cells. The gray cells are the entered data and the yellow ones are the calculated data. The bottom right section is the drawdown test and the bottom left tests for TDH. Drawdown is still the most used procedure for measuring flow in smaller and remote lift stations.įigure 1 shows the pump test portion of the spreadsheet. The one we will review in this article uses a drawdown test to measure pump flow. One uses a flow meter for flow measurement and allows plotting of multiple test points. In order to encourage frequent testing, I developed two, simple submersible pump field test spreadsheets for our customers. In addition to radial loading, operation to the left of BEP can give rise to damaging, suction and discharge recirculation cavitation. This leads to increased shaft deflection which will reduce seal, wear ring and bearing life. ![]() The large width, required for solids passage, increases the radial forces on higher head pumps. Wastewater pumps can be problematic when operated at off BEP conditions due to the size of their impellers. Submersible wastewater pumps can be even more of a problem since they are out of sight and often out of mind. These changes can have a major effect on the pump’s operating point on its H/Q curve. These include malfunctioning gate and check valves, partial blockages in the pipeline, air accumulation at a high point and new branches entering a force main, just to name a few.Ĭlear water systems can face similar challenges but the content of the pumpage makes wastewater systems more vulnerable. E ven if a pump operates at BEP at start up, many conditions will change during the coming months and years. All pumps should be tested regularly, but wastewater pumps are at the top of my list as they are especially susceptible to changing system conditions. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |